Short answer

MULE:CONNECTIVITY means there was a problem establishing a connection. It is the parent of connector errors such as DB:CONNECTIVITY and FTP:CONNECTIVITY, so find the connector named in the log and fix or retry its connection.

VerifiedLast verified

01Error text

MuleSoft error
Error type: MULE:CONNECTIVITY

02Likely causes

  • There was a problem establishing a connection.
  • With no reconnection strategy, the default behavior is for the operation to fail immediately and return a connectivity error.

03How to fix it

  1. Read the namespace of the error in the log, such as DB or FTP, to see which connector failed.
  2. Check that connector's connection configuration for this environment.
  3. Add a reconnection strategy to the connection: <reconnect> retries a set number of times (count, default 2, every frequency milliseconds, default 2000), and <reconnect-forever> keeps trying.
  4. Set failsDeployment="true" on <reconnection> if the app should not deploy when the connection test fails.