Power Automate · Cloud flows: timeout and throttling errors

OperationTimedOut

Short answer

OperationTimedOut in a Power Automate cloud flow: A long-running operation (webhook wait, approval, HTTP polling) exceeded the maximum wait time. The most likely fix is to set explicit timeouts, use relay pattern.

VerifiedLast verified

01Error text

Power Automate error
OperationTimedOut

02Likely causes

  • HTTP webhook action waiting for a callback that never came
  • Approval action without an expiration, hitting the 30-day flow run limit
  • "Delay until" action set to a date beyond the 30-day run duration limit
  • External service went down and never sent the expected response

03How to fix it

  1. Always set explicit timeouts on webhook and approval actions.
  2. For HTTP webhook actions, implement a timeout branch with Configure run after > has timed out.
  3. Break long waits into shorter segments using a loop with daily checks.
  4. For the 30-day run limit, redesign long-running processes to use a "relay" pattern: End the current run and start a new one with state passed via Dataverse or a file.

iNotes

Cloud flows have a maximum run duration of 30 days. For processes that take longer, split them into multiple flow runs with shared state.