Workato · SAP Data Agent
SAP ODP connection timeout (General SAP error UNKNOWN, 500)
Short answer
Either message means the SAP server closed the connection before returning an extraction response, because the ICM timeout is too short for the configured page size. Increase the timeout first, then reduce the page size if it still fails.
VerifiedLast verified
01Error text
General SAP error UNKNOWN: , httpCode = 500, httpCode = 500 INTERNAL_SERVER_ERROR
Connection timed out02Likely causes
- The SAP server closes the connection before returning an extraction response. The ICM timeout is too short for the configured page size.
03How to fix it
- In
RZ10, editicm/server_port_<n>and setTIMEOUTandPROCTIMEOUTto600, for examplePROT=HTTPS,PORT=1443,TIMEOUT=600,PROCTIMEOUT=600. - Restart the SAP application instance.
- If it still fails, reduce Max page by 5,000 in
/WKTO/ODP_CONFIG, remove and re-add the object, and run again. Repeat until it succeeds. - Expect lower throughput with smaller pages.
04Official documentation
→Related errors
- General SAP error RSODP_ODATA/012RSODP_ODATA/012 means SAP hit a problem while extracting a data package for the pipeline. Run the pipeline again.
- Pipeline details not found"Pipeline details not found" from the SAP Table Reader means SAP has no runtime details for the pipeline ID. Verify the pipeline ID and make sure cleanup is not running too early.
- recipe execution takes too longA Workato API platform endpoint returns 504 with recipe execution takes too long when the API recipe's job does not respond within the endpoint's timeout. The default is 30 seconds and the maximum is 240 seconds, so make the recipe faster or raise the endpoint's timeout.
Test every fix in a non-production environment before you apply it to production. See how entries are verified.
More for Workato work:Open Workato jobsWorkato rates and salariesHire a senior Workato developer