Workato · SAP Data Agent

SAP ODP connection timeout (General SAP error UNKNOWN, 500)

Short answer

Either message means the SAP server closed the connection before returning an extraction response, because the ICM timeout is too short for the configured page size. Increase the timeout first, then reduce the page size if it still fails.

VerifiedLast verified

01Error text

Workato error
General SAP error UNKNOWN: , httpCode = 500, httpCode = 500 INTERNAL_SERVER_ERROR

Connection timed out

02Likely causes

  • The SAP server closes the connection before returning an extraction response. The ICM timeout is too short for the configured page size.

03How to fix it

  1. In RZ10, edit icm/server_port_<n> and set TIMEOUT and PROCTIMEOUT to 600, for example PROT=HTTPS,PORT=1443,TIMEOUT=600,PROCTIMEOUT=600.
  2. Restart the SAP application instance.
  3. If it still fails, reduce Max page by 5,000 in /WKTO/ODP_CONFIG, remove and re-add the object, and run again. Repeat until it succeeds.
  4. Expect lower throughput with smaller pages.

04Official documentation

Test every fix in a non-production environment before you apply it to production. See how entries are verified.

More for Workato work:Open Workato jobsWorkato rates and salariesHire a senior Workato developer